Product Detailed
IP67 led power supply, waterproof LED Power Supply, Meanwell power supply gained the CE, UL, CUL certificate. 3 years warranty
Features of LED Power Supply:Universal AC input / Full range (up to 295VAC) Built-in active PFC function High efficiency up to 91% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection OCP point adjustable through output cable or internal IP65 / IP67 design for indoor or outdoor installations Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting 3 years warranty
CLG-150-12 A Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal potentiometer.
Specification Waterproof LED Power Supply, Meanwell Power Supply:
Model | CLG-150-12 | CLG-150-15 | CLG-150-20 | CLG-150-24 | CLG-150-30 | CLG-150-36 | CLG-150-48 | |
Output | DC VOLTAGE | 12V | 15V | 20V | 24V | 30V | 36V | 48V |
CONSTANT CURRENT REGION Note.4 | 9 ~ 12V | 11.25 ~ 15V | 15 ~ 20V | 18 ~ 24V | 22.5 ~ 30V | 27 ~ 36V | 36 ~ 48V | |
RATED CURRENT | 11A | 9.5A | 7.5A | 6.3A | 5A | 4.2A | 3.2A | |
RATED POWER | 132W | 142.5W | 150W | 151.2W | 150W | 151.2W | 153.6W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE Note.6 | 9 ~ 13V | 13 ~ 17V | 17 ~ 22V | 22 ~ 27V | 26 ~ 32V | 31 ~ 41V | 40 ~ 56V | |
CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer or through output cable | |||||||
5.5 ~ 11A | 4.75 ~ 9.5A | 3.75 ~ 7.5A | 3.15 ~ 6.3A | 2.5 ~ 5A | 2.1 ~ 4.2A | 1.6 ~ 3.2A | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | |||||||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP TIME | 3000ms, 80ms at full load 230VAC /115VAC | |||||||
HOLD UP TIME (Typ.) | 50ms / 230VAC 16ms / 115VAC at full load | |||||||
INPUT | VOLTAGE RANGE Note.5 | 90 ~ 295VAC 127 ~ 417VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |||||||
EFFICIENCY (Typ.) | 88% | 88% | 90% | 90% | 91% | 91% | 91% | |
AC CURRENT (Typ.) | 2A / 115VAC; 1A / 230VAC; 0.68A / 277VAC | |||||||
INRUSH CURRENT(max.) | COLD START 65A/230VAC | |||||||
LEAKAGE CURRENT | <1mA / 240VAC | |||||||
PROTECTION | OVER CURRENT (Typ.) Note.4 | 95 ~ 108% | ||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 13.5 ~ 16V | 18 ~ 20V | 23 ~ 27V | 28 ~ 34V | 33 ~ 36V | 42 ~ 48V | 59 ~ 68V | |
Protection type : Shut down and latch off o/p voltage, re-power on to recover | ||||||||
OVER TEMPERATURE | 100°C±10°C(RTH2) | |||||||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70°C (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85°C , 10 ~ 95% RH | |||||||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C ) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||
SAFETY & EMC | SAFETY STANDARDS Note.7 | UL8750, UL1012 ; EN61347-1, EN61347-2-13 independent (except for CLG-150 C type) ; UL60950-1, TUV EN60950-1 ; J61347-1(option, except for CLG-150 C type), J61347-2-13, IP65 or IP67 approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH | |||||||
EMC EMISSION | Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( ≥75% load) ; EN61000-3-3 | |||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A | |||||||
OTHERS | MTBF | 303.7Khrs min. MIL-HDBK-217F (25°C) | ||||||
DIMENSION | 222.2*68*38.8mm (L*W*H)(CLG-150-Blank/A/B) ; 229*68*38.8mm (L*W*H)(CLG-150-C) | |||||||
PACKING | 1.0Kg; 12pcs/13Kg/0.58CUFT(CLG-150-Blank/A/B); 1Kg; 12pcs/13Kg/0.96CUFT(CLG-150-C) | |||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. | |||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||||||
4. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. | ||||||||
5. Derating may be needed under low input voltages. Please check the static characteristics for more details. | ||||||||
6. Type A and type C only. | ||||||||
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. | ||||||||
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. |