Meanwell 150W Single Output Switching Power Supply
Product Detailed
Meanwell LED Driver, Meanwell Power Supply, Meanwell Transformer gained CE,CB, UL certificates. 2 years warranty
Features of Meanwell Driver, Meanwell Power Supply:AC input range selectable by switch Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection LED indicator for power on 100% full load burn-in test High efficiency, long life and high reliability 2 years warranty Specification of Meanwell Transformer:
Model | NES-150-3.3 | NES-150-5 | NES-150-7.5 | NES-150-9 | NES-150-12 | |
Output | DC VOLTAGE | 3.3V | 5V | 7.5V | 9V | 12V |
RATED CURRENT | 30A | 26A | 20A | 16.7A | 12.5A | |
CURRENT RANG | 0 ~ 30A | 0 ~ 26A | 0 ~ 20A | 0 ~ 16.7A | 0 ~ 12.5A | |
RATED POWER | 99W | 130W | 150W | 150W | 150W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | |
VOLTAGE ADJ. RANGE | 3.2 ~ 3.5V | 4.75 ~ 5.5V | 7.13 ~ 8.3V | 8.55 ~ 9.9V | 11.4 ~ 13.5V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | |||||
HOLD UP TIME (Typ.) | 24ms/230VAC ; 0ms/115VAC at full load | |||||
INPUT | VOLTAGE RANGE | 90 ~ 132VAC / 180 ~ 264VAC by switch 254 ~ 373VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
EFFICIENCY(Typ.) | 73% | 78% | 80% | 83% | 83% | |
AC CURRENT (Typ.) | 3A/115VAC 2A/230VAC | |||||
INRUSH CURRENT (Typ.) | COLD START 45A/230VAC | |||||
LEAKAGE CURRENT | <2mA / 240VAC | |||||
PROTECTION | OVERLOAD | 110 ~ 150% rated output power | ||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE | 3.8 ~ 4.65V | 5.75 ~ 6.75V | 8.6 ~ 10.1V | 10.4 ~ 12.2V | 13.8 ~ 16.2V | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||
ENVIRONMENT | WORKING TEMP. | -20 ~ +60°C (Refer to output load derating curve) | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +85°C , 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C ) | |||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||
SAFETY & EMC (Note 6) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1,GB4943 approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 70% RH | |||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B,GB9254 CLASS B | |||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3,GB17625.1 | |||||
EMC IMMUNITY | Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, heavy industry level, criteria A | |||||
OTHERS | MTBF | 433.3Khrs min. MIL-HDBK-217F (25°C ) | ||||
DIMENSION | 199*98*38mm (L*W*H) | |||||
PACKING | 0.7Kg; 20pcs/15Kg/0.72CUFT | |||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | |||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||||
4. Line regulation is measured from low line to high line at rated load. | ||||||
5. Load regulation is measured from 0% to 100% rated load. | ||||||
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives | ||||||
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |